Avalanche® Multi-bottle, Multi-function Sampler
The Avalanche® Sampler is based on the industry-leading 6712 controller. Avalanche provides the advanced control, data logging, and communication features of the 6712, combined with on-the-go cooling from either AC power or a 12-volt deep cycle battery. Bottle configurations include 5 gallon and 2.5 gallon composite as well as 4 x 1 gallon and 14 x 950 ml sequential. 
Like the simpler, composite-only Glacier sampler, Avalanche delivers 48 hours or more of refrigeration from a 12 volt deep cycle battery. Its power-saving cooling system remains on standby until the first sample is drawn, and then switches on to preserve the collected samples until a convenient pickup time. You can easily enter complex programs to suit your unique needs. Available routines include: pause and resume for intermittent discharge flow monitoring; sampler pacing by time, non-uniform time, flow or external event; and random interval sample collection.
Standard Features
- Standard and extended programming keeps setup simple when you don't need advanced features. 
- NEMA 4x, 6 (IP67) controller enclosure is watertight and dustproof. 
- SDI-12 interface provides “plug and play” connection with multi-parameter water-quality sondes and other compatible devices. 
- Standard 512kB memory gives you great flexibility for logging environmental data. 
- NEMA 4X, 6 (IP67) controller enclosure 
- Sample delivery at the EPA-recommended velocity of 2 ft/sec., even at head heights of 26 feet. 
- Patented pump revolution counter ensures accurate sample volumes - and tells you when tubing should be replaced. 
Applications
- Stormwater Runoff Compliance 
- TMDL and Watershed monitoring 
- Enforcement Monitoring 
- Anywhere you need advanced sampling capability combined with data logging and communications for flow, rainfall, and water quality parameters – plus reliable, on-demand cooling. 
Options and Accessories
- Composite sampling bottle configurations - 5-gallon poly bottle 
- 2.5-gallon glass bottle 
- 2.5-gallon poly bottle 
 
- Sequential sampling bottle configurations - 1-gallon poly bottles (4 bottles) 
- 950 ml poly bottles (14 bottles) 
 
- Suction lines and strainers 
- Solar panels for remote installations 
- 674 Rain Gauge 
- 700 Series Modules for flow and parameter measurement 
- Telephone modem for alarm dial out features 
- Cell phone-based data retrieval and dial-out alarm 
- Wireless radio data retrieval with 2102 module 
- 581 RTD data retrieval device 
- Flowlink® Software 
- Optional temperature sensor - provides precise log of sample compartment temperature for automatic documentation 
Avalanche Multi-bottle, Multi-function Sampler
Size (HxWxL): 30.5 x 14 x 24 inches (78 x 36 x 60 cm)
Weight: Dry, less battery - 76 lbs (35 kg)
Power Requirements: 12 VDC, 6 Amps (supplied by external battery), OR 87 to 264 VAC, 47 to 63 Hz, 2 Amps
Cooling: CFC-free refrigeration system maintains sample temperature at 3° C±1°C at ambient temperature of 0°C to 40°C.
Operational Temperatures: 0°C to 50°C
Pump
Intake purge: Adjustable air purge before and after each sample.
Tubing life indicator: Provides a message to change pump tubing.
Intake suction tubing:Length 3 to 99 ft. (1 to 30 m), Vinyl or Teflon® lined, ID 0.375 in.
Pump tubing life: Typically 1,000,000 pump counts
Typical repeatability: ±5 ml or ±5% of the average volume in a set
Maximum lift: 28 ft. (8.5 m)
Typical line velocity @ Head height: 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 12.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m)
Sample presence detector: Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights.
Controller
Weight: 13 lbs. (5.9 kg)
Size: 10 x 12.5 x 10 inches (26 x 32.x 25 cm)
Operational temperature: 32° to 120°F (0° to 49°C)
Enclosure rating: NEMA 4X, 6 (IP67)
Program memory: Non-volatile ROM
Flow meter signal input: 5 to 15 volt DC pulse or 25 millisecond isolated contact closure
External trigger: Initiates sample collection and cooling from contact closure signal
Number of programmable composite samples: 1 to 999 samples
Clock Accuracy: 1 minute per month, typical, for real time clock
Software
Sample frequency selection: 1 minute to 99 hours 59 minutes, in 1 minute increments Non-uniform times in minutes or clock times 1 to 9,999 flow pulses
Sampling modes: Uniform time, non-uniform time, flow, event. (Flow mode is controlled by a flow module or external flow meter pulses.)
Programmable sample volumes: 10 to 9,990 ml in 1 ml increments
Sample Retries: If no sample is detected, up to 3 attempts; user selectable
Rinse Cycles: Automatic rinsing of suction line up to 3 rinses for each sample collection
Program storage: Five sampling programs
Sampling stop/resume: Up to 24 real time/date sample stop/resume commands
Controller diagnostics: Tests for RAM, ROM, pump, and display